Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13670911
| No.13670911
- Product Categories
- Friendly Links
| Information Name: | Supply JD1008-4U2 JD1008-5U2 DC voltage AC voltage transmitter Transmitter |
| Published: | 2015-05-12 |
| Validity: | 30 |
| Specifications: | Optional |
| Quantity: | 1111.00 |
| Price Description: | |
| Detailed Product Description: | Supply JD1008-4U2 JD1008-5U2 DC voltage AC voltage transmitter transmitter digital watthour meter programmable digital electrical measuring instruments 16 42 square groove DRO DRO PA1008-2X1 PA1008-2X4 AC Ammeter AC Ammeter PZ1008-2X1 PZ1008-2X4 AC voltmeter AC voltmeter AC voltmeter PS1008-2X1 PZ1008-2X7 phase active power table PW1008-2X1 PP1008-2X1 three-phase reactive power meter power factor table frequency table PX1008-2X1 PY1008-2X1 power factor angle of the table 96 square DRO PA1008-9X1 AC Ammeter AC Ammeter PZ1008-9X1 PA1008-9X4 PZ1008-9X4 AC voltmeter AC voltmeter PS1008-9X1 phase active power table PW1008-9X1 three-phase reactive power meter PP1008-9X1 power factor table frequency table PX1008-9X1 PY1008-9X1 power factor angle 61 square meter digital meter PA1008-AX1 AC ammeter PA1008-AX4 AC ammeter PZ1008-AX1 AC voltmeter PZ1008-AX4 AC voltmeter PS1008-AX1 phase active power table PW1008-AX1-phase reactive power meter PP1008-AX1 frequency table PX1008-AX1 power factor table PY1008-AX1 power factor angle PA1008-1X1 PP1008-1X1 AC ammeter AC voltmeter frequency table PZ1008-1X1 PX1008-1X1 power factor table PS1008- 1X1 three-phase active power factor angle of the table table PY1008-1X1 PW1008-1X1 phase reactive power 48X48 square DRO PA1008-DX1 AC ammeter PZ1008-DX1 AC voltage AC current transducer JD1008-5I JD1008-4I DC flow AC voltage transmitter Transmitter JD1008-4U JD1008-5U DC voltage transmitter AC current transducer JD1008-5I2 JD1008-4I2 DC current transducer JD1008-4U2 JD1008-5U2 DC voltage AC voltage transmitter Transmitter JD1008-4I3 three-way AC current transducer JD1008-4U3 three-way three-phase AC voltage transmitter JD1008-4P active transmitter JD1008-4Q phase reactive power transmitter transmitter power factor JD1008 JD1008-4H -4D power factor angle transmitter frequency transmitter JD1008-4F Digital Power Meter can replace the conventional power transmitters and measuring instruments. As an advanced intelligent front-end digital capture devices, Digital Power Meter The power meter is widely used in various control systems, SCADA systems and energy management systems. Instrument AC sampling technology to measure grid current, voltage frequency, active power, reactive power, active power, reactive power and other parameters can be set via the membrane switch panel magnification with RS485 communication, alarm output, digital input / output functions. This power meter is designed for power monitoring requirements and power systems, industrial and mining enterprises, public facilities, intelligent buildings, intelligent power monitoring l Operating temperature: LCD display: -10 ℃ ~ + 45 ℃; LED display: -10 ℃ ~ + 55 ℃ l Storage temperature: -20 ℃ ~ + 70 ℃ Relative humidity, etc. l: ≤93% RH, non-condensing, non-corrosive gas l Altitude: ≤2500l C - with RS485 communication interface, using MODBUS protocol, DC4- 20MA signal everywhere 4 optional features l K - with digital input / output l M - Analog Output l J - relay alarm output 1, before using the instrument required power for 15 minutes. 2. Attention to prevent vibration and shock, do not use in a place of excessive dust and excess of harmful gases. 3. Input wire should not be too long, such as the signal input is longer Try shielded twisted pair cable. 4. If the signal is accompanied by high frequency interference, try low-frequency filter online. 5. Long term storage when not in use, the power once every three months at least 4 hours. 6, long-term preservation should avoid direct sunlight, should be stored at ambient temperature -25 ° C ~ 55 ° C. 7, such as instrument no display, you should first check the auxiliary power supply voltage in the range. 8. The display is not normal, check the input signal and the signal terminals tightened. 9. Unless the PT have enough power, or can not use the PT signal at the same time as an auxiliary power to ensure that the instrument work. 10, CT circuit current terminals are tightened to ensure that the inlet / outlet access to reliable, in order to avoid failure. 11. To calibration instruments, calibration equipment should be better than 0.1 in order to ensure that the calibration accuracy. Jiangxi Huajian Power Industry Co., Ltd. Address: Jian Hua Industrial Park, Pingxiang national new material industrial base Innovation Road Tel: 18879975199 0799-3603266 QQ2880925500 Fax: 0799-3609779 Postcode: 337000 Website: www.hjgroup.org |
Admin>>>
You are the 4772 visitor
Copyright © GuangDong ICP No. 10089450, Emil Jiangxi Electric Power Industry Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 4772 visitor
Copyright © GuangDong ICP No. 10089450, Emil Jiangxi Electric Power Industry Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

